Unstable tear movie can considerably sway IOL energy calculation


Thank you for reading this post, don't forget to subscribe!

Key takeaways:

  • Keratometry measurements confirmed important variability in sufferers with unstable tear movie earlier than cataract surgical procedure.
  • Synthetic tears and different applicable remedies ought to be thought-about.

When conducting IOL energy calculation, tear movie instability considerably influences numerous measurements of corneal refractive energy and astigmatism, making errors within the calculation extra possible, in keeping with a research.

“The measurement of corneal refractive energy is without doubt one of the most necessary biometric values for IOL calculation in cataract surgical planning,” Yuanfeng Jiang, of Tianjin Medical College Eye Hospital, China, and colleagues wrote in Advances in Ophthalmology Observe and Analysis. “Though it has been beforehand reported that optical biometry gadgets present pretty dependable measurements of corneal refractive energy in regular eyes, the medical proof concerning their tolerance stage for tear movie instability remains to be inadequate.”



Gao Graphic

When conducting IOL energy calculation, tear movie instability considerably influences numerous measurements of corneal refractive energy and astigmatism, making errors within the calculation extra possible. Picture: Adobe Inventory

Jiang and colleagues carried out a potential observational research of 45 sufferers present process preoperative analysis for age-related cataract surgical procedure.

Sufferers’ tear movies had been assessed utilizing the Keratograph 5M (Oculus). Relying on their noninvasive breakup time, they had been cut up into two teams: these with “secure” or “important” tear movie (n = 23), serving because the management group, and people with “unstable” tear movie (n = 22).

After half-hour, sufferers underwent two consecutive keratometry assessments utilizing the IOLMaster 700 (Zeiss), spaced at the very least 10 minutes aside. The variations between these two measurements had been in contrast between the management group and people with unstable tear movie.

“Earlier researches have virtually all the time interfered with the tear movie itself to some extent when evaluating its stability,” the researchers wrote. “The noninvasive detection methodology utilized in our research efficiently and objectively averted this situation.”

In contrast with the management group, the group with tear movie instability had considerably increased variability in a number of keratometry measurements, together with normal keratometry measures (Kf and Ok), keratometric corneal astigmatism, whole keratometry (TKf and TK) and whole corneal astigmatism.

The one IOL energy calculation method to be considerably affected by these variations was the SRK-T method. Utilizing that method, the IOL energy calculation had a median variability of 0.09 D within the group with tear movie instability and 0.04 D within the management group.

Nonetheless, all formulation included within the IOLMaster 700 (together with the Barrett Common II, Barrett Common II TK, Haigis, Haigis TK and SRK-T TK) confirmed elevated variability as noninvasive breakup time decreased.

General, the outcomes assist “the speculation that an unhealthy tear movie would have a unfavourable impression on corneal measurements,” the researchers wrote.

“Based mostly on noncontact evaluation of tear movie stability, we demonstrated that an unstable tear movie reduces the repeatability of preoperative corneal refractive energy measurements in cataract sufferers, leading to a rise within the variability of IOL calculation formulation,” Jiang and colleagues wrote. “Subsequently, for sufferers with extreme tear movie instability, applicable therapy ought to be actively pursued, resembling the usage of synthetic tears, lipid dietary supplements and biologic tear substitutes.

“Our findings emphasize that ocular floor homeostasis shouldn’t be uncared for in preoperative planning for precision refractive cataract surgical procedure, together with astigmatism administration.”